What causes this: There is dirt or debris in the shut-off valve.

How to fix it:

1. Disassemble the shut-off valve on the wand.

2. Inspect all components for dirt, debris, or damage.

3. Clean all parts thoroughly.

4. Lubricate parts as needed.

5. If cleaning does not resolve the issue, replace the shut-off.

6. Reassemble and test with the lever released to confirm the leak has stopped.

Applies to: HDX Sprayer Models 190804, 190805 (Items #1001896232, #1001896233)

 