Sprayer Only Sprays at Low Pressure (DXSP190786)

Modified on Tue, 15 Sep at 6:19 AM

Applies to: DEWALT 2 Gallon 20V Lithium-ion Powered Sprayer (Model DXSP190786)

 

What causes this: The tank may not be fully pressurized yet, air may be leaking at the tank seal, the tank seal may be damaged, or the nozzle or shut-off may be clogged.

 

How to fix it:

  1. Allow at least 20 seconds for the compressor to pressurize the tank after turning on.
  2. Tighten the compressor to the tank to eliminate air leaks at the seal.
  3. If the tank seal or seal surfaces are damaged, replace the tank seal.
  4. Clean the nozzle. See Nozzle Maintenance.
  5. Clean the shut-off assembly. See Shut-off Assembly Maintenance.

 

Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.