Applies to: DEWALT 2 Gallon 20V Lithium-ion Powered Sprayer (Model DXSP190786)
What causes this: The tank may not be fully pressurized yet, air may be leaking at the tank seal, the tank seal may be damaged, or the nozzle or shut-off may be clogged.
How to fix it:
- Allow at least 20 seconds for the compressor to pressurize the tank after turning on.
- Tighten the compressor to the tank to eliminate air leaks at the seal.
- If the tank seal or seal surfaces are damaged, replace the tank seal.
- Clean the nozzle. See Nozzle Maintenance.
- Clean the shut-off assembly. See Shut-off Assembly Maintenance.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.