Applies to: HDX Bleach and Deck Sprayer (Models 190770 and 190807)
What causes this: The check valve on the bottom of the pump cylinder is unable to seal properly due to dirt, residue, or damage.
How to fix it:
- Release all pressure from the tank before disassembly. Pull up on the pressure release valve knob until all airflow stops.
- Unscrew the pump counterclockwise and remove the entire pump assembly from the tank.
- Examine the check valve on the bottom of the pump cylinder for dirt, residue, or physical damage.
- Clean the check valve with clean water if it is dirty.
- If the check valve is damaged, replace it.
- Reassemble and test the sprayer with plain water before using with chemicals.