Applies to: FGI propane insect foggers sold under the Black Flag, Burgess, Cutter and Repel names (Burgess Portable Propane Insect Fogger, manual 161856; Universal Propane Powered Insect Fogger, manual 180551). Electric foggers are covered separately.
What causes this: The burner is lit and the unit is hot, but nothing comes out. The nozzle or the end of the heating coil is blocked, the pump is plugged or worn, or the wrong fogging material is in the tank.
How to fix it:
- Remove the nozzle and clean the nozzle orifice.
- Remove any carbon build-up from inside the end of the coil. Take the nozzle off and clean the tip of the coil with a brush, a piece of wire, or a pipe cleaner. Reinstall the nozzle after cleaning.
- Clear the pump. On the Burgess 161856, insert a small wire or toothpick into the hole at the bottom of the piston assembly to clear the obstruction. If the pump is still plugged or does not work, replace the pump assembly (161856) or call Customer Service at 1-800-311-9903 (180551).
- If the piston is worn, replace the piston assembly.
- Use only the fogging insecticide named on your carton: Black Flag Fogging Insecticide Formula 2, Cutter, or Repel Fogging Insecticide. Other liquids will not fog properly.
Allow the fogger to cool completely before servicing anything.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.