Applies to: DEWALT 2 Gallon Manual Pump Sprayer (Model DXSP190612)
What causes this: A missing or damaged nozzle seal, a clogged wand or nozzle, or a clogged shut-off filter.
How to fix it:
- Replace the nozzle seal at the end of the wand.
- Remove and clean the wand and nozzle.
- Remove the shut-off hose and clean the filter.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.