Applies to: DEWALT 2 Gallon 20V Lithium-ion Powered Sprayer (Model DXSP190786)
What causes this: The nozzle may be partially clogged or damaged, the tank may not be pressurized, or the shut-off may be clogged.
How to fix it:
- Clean the nozzle. Remove and disassemble, rinse openings with clean water. Do not use sharp tools.
- If cleaning does not restore the spray pattern, replace the nozzle.
- Ensure the compressor is turned on and allow at least 20 seconds for the tank to pressurize.
- Clean the shut-off assembly. See Shut-off Assembly Maintenance.
- Reassemble and test spray pattern.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.