Applies to: Professional 2 Gal Manual Pump Sprayer (Manual No. 183078)

 

What causes this: A damaged piston O-ring, or a dry piston O-ring (Kit #8).

 

How to fix it:

  1. Release all pressure from the tank.
  2. Unscrew and remove the pump assembly.
  3. Inspect the piston O-ring. If damaged, replace it as described in the Pump Disassembly and Reassembly section using Kit #8.
  4. If the O-ring is intact but dry, lubricate it with petroleum jelly.
  5. Reassemble the pump and test. O-rings should be cleaned and lubricated at least once per season.

 

Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.