Sprayer Material Overflows Through Pump Barrel (Smith S103E)

Modified on Tue, 15 Sep at 6:21 AM

Applies to: Smith Performance S103E Stainless Steel Compression Sprayer (Model 190448)

 

What causes this: Dirt or debris under the check valve on the pump, or a chipped, torn, or swollen pump check valve.

 

How to fix it:

  1. Depressurize the sprayer. Squeeze the shut-off lever until all pressure is relieved.
  2. Remove the pump assembly and inspect the check valve (#3T) on the pump. Clean the check valve and the valve sealing surface on the pump.
  3. If the check valve (#3T) is chipped, torn, or swollen, replace it as described in the Pump Disassembly and Reassembly section.
  4. Reassemble the pump and test by pumping to confirm the handle no longer rises when unlocked.

 

Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.