Applies to: HDX Bleach and Deck Sprayer (Models 190770 and 190807)
What causes this: The nozzle or dip tube filter is clogged.
How to fix it:
- Release all pressure from the tank.
- Unscrew the cap nut from the wand and remove the nozzle and nozzle flat seal.
- Remove the dip tube filter from the end of the dip tube.
- Clean the nozzle and dip tube filter with clean water. Do not use sharp tools.
- Reassemble, re-pressurize the tank, and test the spray pattern.
- If the spray pattern is still poor after cleaning, replace the nozzle.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.