Applies to: Smith Performance M200EP Multi-Purpose Acetone Sprayer (Model 190492), acetone compatible
What causes this: Hose clamps may be loose, the hose may be cracked or swollen, or the O-ring at the fitting may be worn.
How to fix it:
- Depressurize the tank first.
- Tighten hose clamps at both the tank and shut-off ends.
- Inspect the hose for cracks, swelling, or damage. Replace if needed with an acetone-compatible hose.
- Replace the O-ring at the hose fitting if worn or missing.
- Re-test with water before using chemicals.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article