Applies to: Smith Performance M200EP Multi-Purpose Acetone Sprayer (Model 190492), acetone compatible
What causes this: Acetone and strong chemicals leave residue that can degrade seals and clog passages if the sprayer is not flushed after use.
How to fix it:
- After every use, depressurize the tank and empty any remaining chemical.
- Rinse the tank with clean water.
- Add about 1 quart of clean water, pressurize, and flush through hose, shut-off, wand, and nozzle until water runs clear.
- For heavy buildup, use warm water with mild detergent and let sit up to 1 hour before rinsing.
- Store empty and depressurized.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.