M200AT Dripless Shut-Off Leaks

Modified on Tue, 15 Sep at 6:21 AM

Applies to: Smith Performance M200AT Dripless Acetone Sprayer (Model 190485), acetone compatible with dripless valve

 

What causes this: The dripless valve relies on Viton seals that can become fouled with residue or degrade from repeated chemical exposure.

 

How to fix it:

  1. Depressurize the tank.
  2. Unscrew and disassemble the dripless shut-off valve.
  3. Rinse all parts with clean water, inspect seals and seats for wear or damage.
  4. Replace seals using the M200AT Shut-Off Repair Kit (Viton, acetone-compatible).
  5. Reassemble, then test with clean water to confirm no drip at release.

 

Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.