Applies to: Smith Performance M200AT Dripless Acetone Sprayer (Model 190485), acetone compatible with dripless valve
What causes this: The dripless valve relies on Viton seals that can become fouled with residue or degrade from repeated chemical exposure.
How to fix it:
- Depressurize the tank.
- Unscrew and disassemble the dripless shut-off valve.
- Rinse all parts with clean water, inspect seals and seats for wear or damage.
- Replace seals using the M200AT Shut-Off Repair Kit (Viton, acetone-compatible).
- Reassemble, then test with clean water to confirm no drip at release.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article