Applies to: Smith Performance M200AT Dripless Acetone Sprayer (Model 190485), acetone compatible with dripless valve
What causes this: Hose clamps may be loose, the hose may be cracked or swollen, or the O-ring may be worn.
How to fix it:
- Depressurize the tank first.
- Tighten hose clamps at both ends.
- Inspect the hose for cracks, swelling, or damage. Replace with acetone-compatible hose if needed.
- Replace the O-ring at the hose fitting if worn.
- Test with water before using chemicals.
Need a part? Order at shop.thefountainheadgroup.com. Warranty claim or registration? thefountainheadgroup.com/register. Anything else, call The Fountainhead Group at 1-800-311-9903.